Pavilion Standards

Alcott Highgate Wright

Material

Treated, Cedar or Pine

Treated, Cedar, Pine or Vinyl

Treated, Cedar or Pine

Roof style

Gable

Hip

Flat

Roof pitch

8/12 pitch

5/12 pitch

1/12 pitch

Roof Cover

Legacy 29 gauge steel (exposed fastener)

Legacy 29 gauge steel (exposed fastener)

Legacy 29 gauge steel (exposed fastener)

Overhangs

10'W-12'W: 12” on gables, 9” on eaves
14'W-20'W: 12" all sides

10’W-12’W 9” all sides
14’W-20’W 12” all sides

15” front, 9” back and 12" on sides

Fascia

6” on gable, none on eave

Treated: none
Vinyl: 6” Azek
Cedar and Pine: none

10'W-12'W: 6" on sides, none on front and back
14'W-16'W: 8" on sides, none on front and back

Posts

Treated: 8”X8” treated, square
Cedar: 8”X8” solid cedar, square
Pine: 8"x8" solid pine, square

Treated: 8”X8” treated, square
Vinyl: 6”X6” treated with vinyl sleeve
Cedar: 8”X8” solid cedar, square
Pine: 8"x8" solid pine, square

Treated: 8”X8” treated, square
Cedar: 8”X8” solid cedar, square
Pine: 8"x8" solid pine, square

Posts placement

Installed on concrete pad (by customer) with mounting brackets

Installed on concrete pad (by customer) with mounting brackets

Installed on concrete pad (by customer) with mounting bracket

Beam

Treated: 4”X10” solid
Cedar and Pine: 4”X12” solid

Treated: 4”X10” solid
Vinyl: (2) 2”X12” wrapped in Azek
Cedar and Pine: 4”X12” solid

Treated: 4”X10” solid
Cedar and Pine: 4”X12” solid

Base to bottom of beam measurement
Floor option reduces this measurement by 8".

7’6”

7’6”

7’6” (back beam)

Rafters

4”X6”
(20’ and longer have a center truss with post)

Treated: 4"X6"
Vinyl: 10'W-12'W 2"X6", 14'W-20'W 2"X8"
Cedar and Pine: 4"X6"

10'W-12'W: 4"X6"
14'W-16'W: 4"X8"

Sheathing

1"x8” T&G pine

Treated, Cedar and Pine: 1"x8” T&G pine
Vinyl: 7/16” OSB

1"x8” T&G pine

Ceiling

Open, exposed rafters

Treated, Cedar and Pine: Open, exposed rafters
Vinyl: Closed, 1”X6” T&G pine (with Cedartone Stain)

Open, exposed rafters

Bracing

Straight corner braces

Straight corner braces
(N/A for vinyl)

Straight corner braces

Hardware

None (new for 2025)
Call for special pricing.

None (new for 2025)
Call for special pricing.

None (new for 2025)
Call for special pricing.

Pre-engineered
Some exclusions apply.

Treated and Cedar: Yes
Pine: No

Treated, Cedar and Vinyl: Yes
Pine: No

Treated and Cedar: Yes
Pine: No

Pergola Standards

Cardiff Parkhurst

Material

Treated or Cedar

Vinyl

Roof slats

2”x2” - 5” on center

None

Rafters

4”x6”

10’W-12’W: Aluminum H-channel vinyl-clad, 2”x6”
14’W-16’W: 2”x6” Treated vinyl-clad

Beam

Treated: 4”x10”
Cedar: 4”x12”

10’-12’: Aluminum H-channel vinyl-clad, 2”x8”
14’-24’: 2”x8” Treated vinyl-clad

Posts

8”x8”

6”x6” Treated vinyl-clad

Post placement

Installed on concrete pad (by customer) with mounting brackets.

Installed on concrete pad (by customer) with mounting brackets.

Base to bottom of beam measurement
Floor option reduces this measurement by 8"

7’6”

8’

Hardware

None (new for 2025)
Call for special pricing

N/A

Pre-engineered
Some exclusions apply.

Yes

No